Inspection Information:
Facility Type: | Swimming Pool/Waterslide (>19 sq.m) |
Inspection type: | Routine |
Inspection date: | July 21, 2014 |
Follow-up Required: | Yes |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) |
Chlorine (Free Available) 2.08ppm |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.6 |
Total Alkalinity 111ppm |
Total Hardness 336ppm |
Temperature 83F |
Clarity Main drain clearly visable |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
401 | Note Violation Observation: Non - GFCI outlet observed on pool deck. Corrective Action: Replace with GFCI outlet to prevent possible electrocution hazard. |
401 | Note Violation Observation: - Vacuum breakers not in place on all pool deck hose bibbs, or on change room hose bibbs. Corrective Action: Install vacuum breakers/backflow prevention devices on all hose bibbs in pool areas. |
401 | Note Violation Observation: Non - GFCI outlet observed on pool deck. Corrective Action: Replace with GFCI outlet to prevent possible electrocution hazard. |
401 | Note Violation Observation: - Vacuum breakers not in place on all pool deck hose bibbs, or on change room hose bibbs. Corrective Action: Install vacuum breakers/backflow prevention devices on all hose bibbs in pool areas. |