Aspen Motor Inn - Swimming Pool - Inspection Report

Inspection Information:
Facility Type:  Swimming Pool/Waterslide (>19 sq.m)
Inspection type:  Routine
Inspection date:  October 19, 2004
Follow-up Required:  Yes

This facility was given a high hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
Chlorine (Free Available)
>15ppm
Chlorine (Combined)
Bromine (Free Available)
pH
>8.0
Total Alkalinity
Total Hardness
Temperature
Clarity
Good
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
400  Critical Improper suction line or fitting
Observation: Recirculation system does not appear to be working properly. No suction is present within skimmer.
402  Critical Inadequate pH controls
Observation: pH is measured at >8.0.
413  Critical Other (specify below)
Observation: No Floating weir/floating ring is found within skimmer to help ensure one-way flow of water.