Aspen Motor Inn - Hot Tub - Inspection Report

Inspection Information:
Facility Type:  Hot Tub/Therapeutic Pool (<19 sq.m)
Inspection type:  Routine
Inspection date:  May 08, 2018
Follow-up Required:  Yes

This facility was given a low hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
Chlorine (Free Available)
Chlorine (Combined)
Bromine (Free Available)
pH
7.6
Total Alkalinity
184
Total Hardness
Temperature
38C
Clarity
Good
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
101  Critical Improper Water Chemistry/Water Clarity
Observation: The concentration of cyanuric acid was measured at over 200ppm.
Corrective Action: If using stabilized chlorine tablets for an indoor facility ensure that the concentration of the cyanuric acid does not exceed 80ppm and is monitored and recorded on a weekly basis as is required by regulation.
101   Improper Water Chemistry/Water Clarity
Observation: The total alkalinity of the hot tub was measured at 184 ppm.
Corrective Action: Ensure that the total alkalinity falls within the 80-120ppm range and is tested and recorded on a weekly basis. Having an alkalinity outside of this range can cause rapid fluctuations in pH, resulting in a loss of disinfectant availability.