Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Follow-Up |
Inspection date: | March 22, 2006 |
Follow-up Required: | Yes |
This facility was given a high hazard rating.
More information on hazard ratings.
Chlorine (Total) 3 |
Chlorine (Free Available) 1 |
Chlorine (Combined) |
Bromine (Free Available) |
pH >8.0 |
Total Alkalinity |
Total Hardness |
Temperature |
Clarity Good |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
401 | Critical Inadequate concentration of disinfectant Observation: High concentration of combined chlorine (2ppm). Corrective Action: Maintain combined chlorine residual at less than 1ppm at all times while the pool is in operation. |
402 | Critical Inadequate pH controls Observation: pH of pool water is measured to be greater than 8.0. Corrective Action: pH should be maintained at less than 7.8 at all times while the pool is in operation. Recommended pH range is 7.4 - 7.8. |
413 | Critical Other (specify below) Observation: Chemical parameters are not being monitored and recorded every 4 hours as required. Corrective Action: Monitor and record pH and concentration of free available chlorine every 4 hours. |
414 | Repeat Lack of automatic disinfection equipment Observation: No system of automatic disinfection. Corrective Action: A system of automatic disinfection is required. No stabilized chlorine pucks are to be used. |