Inspection Information:
Facility Type: | Swimming Pool/Waterslide (>19 sq.m) |
Inspection type: | Routine |
Inspection date: | January 26, 2006 |
Follow-up Required: | Yes |
This facility was given a high hazard rating.
More information on hazard ratings.
Chlorine (Total) 5 |
Chlorine (Free Available) 4 |
Chlorine (Combined) |
Bromine (Free Available) |
pH >8.0 |
Total Alkalinity 220 ppm |
Total Hardness |
Temperature |
Clarity Good |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
402 | Critical Inadequate pH controls Observation: pH is measured to be greater than 8.0. Corrective Action: pH is to be maintained below 7.8. Recommended pH range is 7.4 - 7.6. |
413 | Critical Repeat Other (specify below) Observation: Only 1 skimmer is present - no main drain. Corrective Action: A main drain is required. |
413 | Critical Repeat Other (specify below) Observation: Total alkalinity is measured to be 220ppm. Corrective Action: A high concentration of total alkalinity may lead to an increasing level of pH. Adjust total alkalinity to between 120 - 180ppm. |
421 | Other (specify below) Observation: Pool operator is not certified in pool operation and maintenance. Corrective Action: At least one staff member must be certified in pool operation and maintenance. |