Houston Leisure Facility - Main Pool - Inspection Report

Inspection Information:
Facility Type:  Swimming Pool/Waterslide (>19 sq.m)
Inspection type:  Routine
Inspection date:  January 18, 2008
Follow-up Required:  No

This facility was given a low hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
3.0ppm
Chlorine (Free Available)
2.5ppm
Chlorine (Combined)
Bromine (Free Available)
pH
7.4
Total Alkalinity
40ppm
Total Hardness
Temperature
Clarity
Good
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
421   Other (specify below)
Observation: Total alkalinity is measured to be 40ppm. The recommended range is 80 - 120ppm.
Corrective Action: Increase total alkalinity to 80ppm. Low total alkalinity can cause pH bounce.