Houston Leisure Facility - Leisure Pool - Inspection Report

Inspection Information:
Facility Type:  Swimming Pool/Waterslide (>19 sq.m)
Inspection type:  Routine
Inspection date:  March 03, 2016
Follow-up Required:  No

This facility was given a low hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
Chlorine (Free Available)
3.02 ppm
Chlorine (Combined)
Bromine (Free Available)
pH
7.67 pH
Total Alkalinity
104 ppm
Total Hardness
Temperature
Clarity
Main drain clearly visible
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
101   Improper Water Chemistry/Water Clarity
Observation: - Combined chlorine concentration measured > 1.0ppm at 1.59 ppm with EHO test kit. Operator's records showed that combined chlorine concentration was 0.5ppm. Leisure pool breakpoint chlorination procedures are completed weekly.
Corrective Action: - Increase frequency as required. Please breakpoint chlorinate as soon as possible. Inform the undersigned upon completion.
101   Improper Water Chemistry/Water Clarity
Observation: - Combined chlorine concentration measured > 1.0ppm at 1.59 ppm with EHO test kit. Operator's records showed that combined chlorine concentration was 0.5ppm. Leisure pool breakpoint chlorination procedures are completed weekly.