Comfort Inn & Suites - Inspection Report

Inspection Information:
Facility Type:  Hot Tub/Therapeutic Pool (<19 sq.m)
Inspection type:  Routine
Inspection date:  May 28, 2019
Follow-up Required:  Yes

This facility was given a low hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
.14
Chlorine (Free Available)
.13
Chlorine (Combined)
Bromine (Free Available)
pH
7.85
Total Alkalinity
210
Total Hardness
Temperature
38.8 C
Clarity
Cloudy
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
101   Improper Water Chemistry/Water Clarity
Observation: Alkalinity was measured at 210 ppm. Alkalinity should be maintained between 80-120 ppm according to the BC Pool Regulation.
Corrective Action: Adjust and maintain the alkalinity within the range of 80-120 ppm.
101   Improper Water Chemistry/Water Clarity
Observation: pH was measured at 7.85. This is above the required range according to the BC Pool Regulation of 7.2 -7.8.
Corrective Action: Adjust and maintain the pH between 7.2-7.8.
101  Critical Improper Water Chemistry/Water Clarity
Observation: Free Chlorine was measured at .13 ppm. Free chlorine must be maintained at a minimum of 1.5 ppm to provide adequate disinfection to the pool.
Corrective Action: Adjust and maintain free chlorine levels at a minimum of 1.5 ppm.
205   Improper Monitoring of Chemical Paramaters or Safety Tests
Observation: Log of pool chemistry parameters was not maintained daily. Pool chemistry tests needs to be done and recorded twice daily for chlorine and pH, and twice weekly for total alkalinity.
Corrective Action: Ensure log book and testing of parameters is consistent and recorded.
401   Note Violation
Observation: Permit was not posted in the pool room. The operating permit must be posted in a prominent location for patrons to see.
Corrective Action: Place permit in a visible location in the pool room.