Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Routine |
Inspection date: | July 16, 2014 |
Follow-up Required: | No |
This facility was given a moderate hazard rating.
More information on hazard ratings.
Chlorine (Total) |
Chlorine (Free Available) >10 ppm |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.6 |
Total Alkalinity 82 ppm |
Total Hardness 133 ppm |
Temperature 42°C |
Clarity |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: FAC(Free available chlorine) measured greater than 10 ppm at the time of inspection. This concentration could be irritating to pool patrons. Corrective Action: Lower FAC to 3 - 5 ppm. Corrected. 3.71 FAC. |
103 | Improper Pool Temperature Observation: Hot tub temperature measured 42°C at the time of inspection.Hub tub temperatures greater than 40°C, put patrons at risk of overheating. Corrective Action: Lower hot tub temperature to a maximum of 40°C. Corrected. 37.1°C. |
203 | Inadequate or Lack of up-to-date Pool Safety Plan Observation: No pool safety plan was available at the time of inspection. Corrective Action: Complete and submit a copy of your pool safety plan to the undersigned by August 2014. A copy of a safety plan template will be emailed to operator. |
401 | Note Violation Observation: Floating weir was not observed to be in place at the time of inspection. This keeps objects from re-entering the pool from the strainer basked if suction is lost. Corrective Action: Weir has been ordered. Replace floating weir in strainer basket, |
101 | Improper Water Chemistry/Water Clarity Observation: FAC(Free available chlorine) measured greater than 10 ppm at the time of inspection. This concentration could be irritating to pool patrons. Corrective Action: Lower FAC to 3 - 5 ppm. Corrected. 3.71 FAC. |
103 | Improper Pool Temperature Observation: Hot tub temperature measured 42°C at the time of inspection.Hub tub temperatures greater than 40°C, put patrons at risk of overheating. Corrective Action: Lower hot tub temperature to a maximum of 40°C. Corrected. 37.1°C. |
203 | Inadequate or Lack of up-to-date Pool Safety Plan Observation: No pool safety plan was available at the time of inspection. Corrective Action: Complete and submit a copy of your pool safety plan to the undersigned by August 2014. A copy of a safety plan template will be emailed to operator. |
401 | Note Violation Observation: Floating weir was not observed to be in place at the time of inspection. This keeps objects from re-entering the pool from the strainer basked if suction is lost. Corrective Action: Weir has been ordered. Replace floating weir in strainer basket, |