Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Routine |
Inspection date: | April 04, 2018 |
Follow-up Required: | No |
This facility was given a high hazard rating.
More information on hazard ratings.
Chlorine (Total) Excessive |
Chlorine (Free Available) Excessive |
Chlorine (Combined) |
Bromine (Free Available) N/A |
pH 7.72 |
Total Alkalinity 66 ppm |
Total Hardness N/A |
Temperature 37°C |
Clarity |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Critical Improper Water Chemistry/Water Clarity Observation: Stablized chlorine meant for outdoor was used for an indoor hot tub.Levels of stablizer (cyanuric acid) was excessive. This creates a "chlorine lock", rendering the disinfectant ineffective. Corrective Action: Operation mentioend the calcium hypochloride was making the pool cloudy. The hot tub must be drained and refilled with fresh water. A non-stablized chlorine product must be used going forward. |
101 | Critical Improper Water Chemistry/Water Clarity Observation: Stablized chlorine meant for outdoor was used for an indoor hot tub.Levels of stablizer (cyanuric acid) was excessive. This creates a "chlorine lock", rendering the disinfectant ineffective. Corrective Action: Operation mentioend the calcium hypochloride was making the pool cloudy. The hot tub must be drained and refilled with fresh water. A non-stablized chlorine product must be used going forward. |