Houston Leisure Facility - Leisure Pool - Inspection Report

Inspection Information:
Facility Type:  Swimming Pool/Waterslide (>19 sq.m)
Inspection type:  Routine
Inspection date:  October 18, 2018
Follow-up Required:  Yes

This facility was given a moderate hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
3.22 ppm
Chlorine (Free Available)
1.76 ppm
Chlorine (Combined)
Bromine (Free Available)
pH
7.63
Total Alkalinity
110 ppm
Total Hardness
Temperature
33 C
Clarity
Good
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
101   Improper Water Chemistry/Water Clarity
Observation: Combined chlorine tested at 1.46 ppm at time of inspection. Staff tested combined chlorine at 1.5 ppm. Pool was immediately closed. Facility procedure is to breakpoint chlorinate the pool at the end of the night for a duration of 12 hours. Follow the procedures explained in the Pool Safety Plan on-site to lower combined chlorine and maintain a pH between 7.2 and 7.8.
Corrective Action: Ensure combined chlorine is maintained below 1 ppm before leisure pool can be re-opened.