Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Follow-Up |
Inspection date: | June 28, 2019 |
Follow-up Required: | Yes |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) >5 |
Chlorine (Free Available) >5 |
Chlorine (Combined) |
Bromine (Free Available) |
pH >8.4 |
Total Alkalinity 36 |
Total Hardness |
Temperature |
Clarity Good |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: pH tested >8.4 and total alkalinity tested at 36 mg/L at time of inspection. Corrective Action: pH must be maintained between 7.2 and 7.8 at all times while the hot tub is in operation. Total alkalinity must be kept between 80 and 120 mg/L. |