Chalet Continental - Inspection Report

Inspection Information:
Facility Type:  Hot Tub/Therapeutic Pool (<19 sq.m)
Inspection type:  Follow-Up
Inspection date:  September 16, 2010
Follow-up Required:  Yes

This facility was given a moderate hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
.2
Chlorine (Free Available)
0
Chlorine (Combined)
Bromine (Free Available)
pH
7.0
Total Alkalinity
Total Hardness
Temperature
Clarity
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
401  Critical Inadequate concentration of disinfectant
Observation: 1. TAC 0.2ppm FAC 0 CC 0.2ppm. Close the hot tub until the next inspection. 2. Cyanuric Acid 70ppm.
Corrective Action: 1. Adjust and maintain chlorine concentration to >3ppm. 2. Stabilized chlorine should not be used in this tub.
414   Lack of automatic disinfection equipment
Observation: The present auto injection system for chlorine is not working adequately.
Corrective Action: Submit plans for installing an automatic chlorine injection system by October 31, 2010.
415   Inadequate water turnover rate
Observation: The tub circulation was turned off in the morning. Staff say they are instructed to turn off the pumps at night when they close the pool room.
Corrective Action: Always keep the circulation pump on to maintain filtration and disinfection.