Inspection Information:
Facility Type: | Swimming Pool/Waterslide (>19 sq.m) |
Inspection type: | Routine |
Inspection date: | October 18, 2018 |
Follow-up Required: | Yes |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 4.00 ppm |
Chlorine (Free Available) 3.77 ppm |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.77 |
Total Alkalinity 27 ppm |
Total Hardness |
Temperature 40°C |
Clarity Satisfactory |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: Total Alkalinity tested at 27 ppm. Corrective Action: Adjust total alkalinity and maintain between 80 ppm - 120 ppm. |
401 | Note Violation Observation: Flow meter not functioning at the time of the inspection. Flow rate of reciruclating water could not be determined. Flow rate must be monitored to ensure adequate turnover of water and to ensure that the water velocity through the main drain does not present a suction hazard. Corrective Action: Please repair or replace flow meter to ensure an accurate flow rate is indicated. . |
101 | Improper Water Chemistry/Water Clarity Observation: Total Alkalinity tested at 27 ppm. Corrective Action: Adjust total alkalinity and maintain between 80 ppm - 120 ppm. |
401 | Note Violation Observation: Flow meter not functioning at the time of the inspection. Flow rate of reciruclating water could not be determined. Flow rate must be monitored to ensure adequate turnover of water and to ensure that the water velocity through the main drain does not present a suction hazard. Corrective Action: Please repair or replace flow meter to ensure an accurate flow rate is indicated. . |