Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Routine |
Inspection date: | October 15, 2020 |
Follow-up Required: | Yes |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 5.69 |
Chlorine (Free Available) 5.14 |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.86 |
Total Alkalinity 19 |
Total Hardness |
Temperature 41.6°C |
Clarity Good, Clear |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: Total alkalinity of the hot tub measured at 19 ppm. Corrective Action: Adjust and ensure total alkalinity is maintained between 80-120 ppm. |
103 | Improper Pool Temperature Observation: Temperature of hot tub measured at 41.6°C. Corrective Action: Adjust and ensure temperature of the hot tub does not exceed 40°C. |
205 | Improper Monitoring of Chemical Paramaters or Safety Tests Observation: Chemical testing reagents were expired. Corrective Action: Ensure that chemical testing reagents are used within their expiry date for accurate results. |