Houston Leisure Facility - Leisure Pool - Inspection Report

Inspection Information:
Facility Type:  Swimming Pool/Waterslide (>19 sq.m)
Inspection type:  Follow-Up
Inspection date:  July 31, 2006
Follow-up Required:  Yes

This facility was given a low hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
0.5
Chlorine (Free Available)
1.5
Chlorine (Combined)
Bromine (Free Available)
pH
7.6
Total Alkalinity
60ppm
Total Hardness
Temperature
Clarity
Good
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
401  Critical Inadequate concentration of disinfectant
Observation: Concentration of free available chlorine is at the minimum required concentration of 0.5ppm.
Corrective Action: Increase concentration of free available chlorine immediately. Completed at the time of inspection.
421   Other (specify below)
Observation: Total alkalinity is measured to be 60ppm.
Corrective Action: Total alkalinity should be maintained within the range of 80 - 120ppm. Low total alkalinity can cause pH levels to fluctuate.
421   Other (specify below)
Observation: Safety equipment is not properly mounted in the facility.
Corrective Action: Ensure all lifesaving equipment is mounted in a conspicuous place and is ready for use at all times.
421   Other (specify below)
Observation: Sanitary receptacles in ladies washroom do not have inserts.
Corrective Action: Ensure proper inserts are in place in all garbage receptacles to ensure the sanitary disposal of garbage.