Earl Mah Aquatic Centre (Main Pool) - Inspection Report

Inspection Information:
Facility Type:  Swimming Pool/Waterslide (>19 sq.m)
Inspection type:  Complaint
Inspection date:  February 03, 2017
Follow-up Required:  Yes

This facility was given a moderate hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
3.63
Chlorine (Free Available)
2.09
Chlorine (Combined)
Bromine (Free Available)
pH
Total Alkalinity
Total Hardness
Temperature
Clarity
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
101   Improper Water Chemistry/Water Clarity
Observation: Combined chlorine measured at 1.49 and 1.54 ppm. Maximimum allowable limit is 1 ppm.
Corrective Action: To bring this down please superchlorinate pool to 15 ppm chlorine and maintain this concentration for 6 hours. Pool to remain closed until the chlorine dissapates and the combined chlorine is below 1ppm with the Palintest.
101   Improper Water Chemistry/Water Clarity
Observation: Combined chlorine measured at 1.49 and 1.54 ppm. Maximimum allowable limit is 1 ppm.
Corrective Action: To bring this down please superchlorinate pool to 15 ppm chlorine and maintain this concentration for 6 hours. Pool to remain closed until the chlorine dissapates and the combined chlorine is below 1ppm with the Palintest.