Tumbler Ridge Aquatic Centre Main Pool - Inspection Report

Inspection Information:
Facility Type:  Swimming Pool/Waterslide (>19 sq.m)
Inspection type:  Routine
Inspection date:  August 08, 2023
Follow-up Required:  Yes

This facility was given a low hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
2.25
Chlorine (Free Available)
1.34
Chlorine (Combined)
Bromine (Free Available)
pH
7.48
Total Alkalinity
71
Total Hardness
Temperature
30.1
Clarity
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
101   Repeat Improper Water Chemistry/Water Clarity
Observation: Total alkalinity was measured at 71 ppm. Re-test showed a concentration of 61 ppm. Low alkalinity can result in pH bounce, where pH fluctuates, affecting the ability of free chlorine to disinfect pool water. Maintaining free chlorine is important to reduce harmful microbes in pool water.
Corrective Action: Operator to adjust alkalinity so it remains between 80 ppm to 120 ppm. Continue to monitor and record alkalinity at least once a week.
306   Improper Handrails, Ladders, and/or Diving Boards
Observation: Handrail located at the deep end near the first aid room is not secured. Handrail should be secure to prevent possible slipping or falling hazard and injury to swimmers who are using the pool
Corrective Action: Operator to secure the handrail.