Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Follow-Up |
Inspection date: | July 23, 2019 |
Follow-up Required: | No |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) |
Chlorine (Free Available) |
Chlorine (Combined) |
Bromine (Free Available) |
pH |
Total Alkalinity |
Total Hardness |
Temperature |
Clarity |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: pH and free available chlorine were tested. pH was found to be at 8.19 and free available chlorine was found to be at 0.85 ppm. Corrective Action: The operator adjusted the water chemistry while on site. The free available chlorine was found to be at 8 to 10 ppm after the adjustment and pH was reduced by adding pH minus while on site. The operator stated that they will test for the water chemistry again tomorrow to ensure parameters were within the regulatory limits. |
306 | Improper Handrails, Ladders, and/or Diving Boards Observation: Handrail was loose at the hot tub. Corrective Action: Handrails must be securely installed to prevent further deterioration |