Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Routine |
Inspection date: | July 26, 2016 |
Follow-up Required: | No |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 5.7 |
Chlorine (Free Available) 3.5 |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.6 |
Total Alkalinity 80 |
Total Hardness |
Temperature 39°C |
Clarity Clear |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Critical Improper Water Chemistry/Water Clarity Observation: Combined chlorine at 2.2 during time of inspection Corrective Action: Please ensure to maintain a combined chlorine concentration of less than 1.0 during times of high bather load. Operator has stated he will shock chlorinate the tub to reduce the combined chlorines. |