Ramada Hotel Hot Tub - Inspection Report

Inspection Information:
Facility Type:  Hot Tub/Therapeutic Pool (<19 sq.m)
Inspection type:  Follow-Up
Inspection date:  August 11, 2005
Follow-up Required:  No

This facility was given a low hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
3.5
Chlorine (Free Available)
1.5
Chlorine (Combined)
Bromine (Free Available)
pH
7.6
Total Alkalinity
Total Hardness
Temperature
Clarity
clear
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
401  Critical Inadequate concentration of disinfectant
Observation: Combined chlorine = 2.0 which is more than 50% of total.
412  Critical Improper or lack of cross-connection prevention devices
Observation: Hose bib at pool requires a backflow preventer. Hose bib in filter room for hose into hot tub chlorine solution, requires a backflow preventer.
417   Inadequate maintenance of pool equipment
Observation: Flow rate meter has been ordered.
421   Other (specify below)
Observation: Skimmer basket has been ordered.