Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Routine |
Inspection date: | April 02, 2019 |
Follow-up Required: | No |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 2.48 ppm |
Chlorine (Free Available) 2.04 ppm |
Chlorine (Combined) |
Bromine (Free Available) N/A |
pH 7.76 |
Total Alkalinity 57 ppm |
Total Hardness N/A |
Temperature 39.1 C (102.4 F) |
Clarity Clear; good |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: Total Alkalinity was measured to be 57 ppm. Low total alkalinity can result in difficulties stabilizing pH, corrosion, and skin and/or eye irritation. Corrective Action: Ensure total alkalinity is maintained between 80 ppm to 120 ppm as per the Pool Regulation. |