Inspection Information:
Facility Type: | Swimming Pool/Waterslide (>19 sq.m) |
Inspection type: | Routine |
Inspection date: | May 30, 2017 |
Follow-up Required: | No |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 1.6 |
Chlorine (Free Available) 1.4 |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.4 |
Total Alkalinity 70 |
Total Hardness |
Temperature 85F |
Clarity Clear |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
401 | Note Violation Observation: Pool Flowmeter is not funtional. Operator had tried to correct the flowmeter but it was not working and was reading an inaccurate number. It is the operator's responsibility to ensure that their pool operators at the ideal flow rate in order to prevent an increased risk of suction hazard occurring. In order to do this, you must know your ideal flow rate and be able to measure the current outgoing flow Corrective Action: Install a new flowmeter and ensure it is functional at all times on a routine basis. Pool Ideal Flow Rate is listed at 41.5 GPM and it is your responsibility to confirm this during checks. |
401 | Note Violation Observation: Pool Flowmeter is not funtional. Operator had tried to correct the flowmeter but it was not working and was reading an inaccurate number. It is the operator's responsibility to ensure that their pool operators at the ideal flow rate in order to prevent an increased risk of suction hazard occurring. In order to do this, you must know your ideal flow rate and be able to measure the current outgoing flow Corrective Action: Install a new flowmeter and ensure it is functional at all times on a routine basis. Pool Ideal Flow Rate is listed at 41.5 GPM and it is your responsibility to confirm this during checks. |