Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Routine |
Inspection date: | July 21, 2015 |
Follow-up Required: | No |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 1.0 (1.53) |
Chlorine (Free Available) |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.1 |
Total Alkalinity 8 |
Total Hardness |
Temperature 39.3°C |
Clarity Main drain visible |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: Free Available Chlorine was measured at 1.1 ppm at time of inspection. There was a high bather volume when measurements were taken. Alkalinity measeured at 8 should be 80-120ppm. Corrective Action: Please ensure whirlpool maintains Free Available Chlorine concentration of at lease 1.5ppm (really 3-5ppm) even during busy hours.Adjust the alkalinity accordingly. |
104 | Improper Turnover of Flow Rate Observation: Flow meter reading=1100 LPM. Ideal flow rate (5000 Gal whirl pool)=946 LPM Corrective Action: Please review the ideal flow rates and adjust accordingly so as to avoid creating a suction hazard. |
101 | Improper Water Chemistry/Water Clarity Observation: Free Available Chlorine was measured at 1.1 ppm at time of inspection. There was a high bather volume when measurements were taken. Alkalinity measeured at 8 should be 80-120ppm. Corrective Action: Please ensure whirlpool maintains Free Available Chlorine concentration of at lease 1.5ppm (really 3-5ppm) even during busy hours.Adjust the alkalinity accordingly. |
104 | Improper Turnover of Flow Rate Observation: Flow meter reading=1100 LPM. Ideal flow rate (5000 Gal whirl pool)=946 LPM Corrective Action: Please review the ideal flow rates and adjust accordingly so as to avoid creating a suction hazard. |