Inspection Information:
Facility Type: | Swimming Pool/Waterslide (>19 sq.m) |
Inspection type: | Routine |
Inspection date: | January 16, 2007 |
Follow-up Required: | No |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 3 |
Chlorine (Free Available) 2 |
Chlorine (Combined) |
Bromine (Free Available) - |
pH 7.4 |
Total Alkalinity 60ppm |
Total Hardness - |
Temperature |
Clarity Good |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
421 | Other (specify below) Observation: Total alkalinity is measured to be 60ppm. The recommended range is 80 - 120ppm. Low total alkalinity can contribute to pH bounce. Corrective Action: Increase total alkalinity to 80ppm. Monitor total alkalinity at least once per week. Record test results on data sheet. |