Inspection Information:
Facility Type: | Swimming Pool/Waterslide (>19 sq.m) |
Inspection type: | Routine |
Inspection date: | April 26, 2017 |
Follow-up Required: | Yes |
This facility was given a low hazard rating.
More information on hazard ratings.
Chlorine (Total) 4.46 ppm |
Chlorine (Free Available) 3.89 ppm |
Chlorine (Combined) |
Bromine (Free Available) |
pH 7.9 |
Total Alkalinity 160 ppm |
Total Hardness |
Temperature 26 °C |
Clarity Adequate |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
101 | Improper Water Chemistry/Water Clarity Observation: pH was measured to be 7.9. High pH reduces the effectiveness of chlorine disinfectant. Corrective Action: Reduce pH to within 7.2 - 7.8 range |
305 | Improper Maintenance of Pool Surface, Walkways, Floors and/or Construction Observation: Floating weir missing from skimmer (on opposite side of pool from entrance and gymnasium). Weir must be in place to ensure effective removal of surface contaminants. Corrective Action: Replace weir |
305 | Improper Maintenance of Pool Surface, Walkways, Floors and/or Construction Observation: Handrail next to pool steps was loose. Handrail must be secure to assist bathers safely entering or exiting the pool. Corrective Action: Secure handrail |
101 | Improper Water Chemistry/Water Clarity Observation: pH was measured to be 7.9. High pH reduces the effectiveness of chlorine disinfectant. Corrective Action: Reduce pH to within 7.2 - 7.8 range |
305 | Improper Maintenance of Pool Surface, Walkways, Floors and/or Construction Observation: Floating weir missing from skimmer (on opposite side of pool from entrance and gymnasium). Weir must be in place to ensure effective removal of surface contaminants. Corrective Action: Replace weir |
305 | Improper Maintenance of Pool Surface, Walkways, Floors and/or Construction Observation: Handrail next to pool steps was loose. Handrail must be secure to assist bathers safely entering or exiting the pool. Corrective Action: Secure handrail |