Sandman Hotel Hot Tub - Inspection Report

Inspection Information:
Facility Type:  Hot Tub/Therapeutic Pool (<19 sq.m)
Inspection type:  Routine
Inspection date:  March 13, 2023
Follow-up Required:  Yes

This facility was given a moderate hazard rating.
More information on hazard ratings.

Field Tests
Chlorine (Total)
>10 ppm
Chlorine (Free Available)
5.35 ppm
Chlorine (Combined)
Bromine (Free Available)
pH
6.5
Total Alkalinity
53 ppm
Total Hardness
Temperature
39.6
Clarity
Good
Cyanuric Acid

Violations:
A summary of the violations found during the inspection are listed below.

Code   Description / Observation / Corrective Action
101  Critical Improper Water Chemistry/Water Clarity
Observation: pH observed at 6.5 (ideal range 7.2-7.8). (Public Health significance) Low pH can cause rapid drop in chlorine residual, lead to corrosive water and metals, cause Fe and Cu deposition in water, reduces the Total Alkalinity of the water and water becomes irritant to eyes/skin to patrons.
Corrective Action: Bring the water pH to the regulatory range (7.2-7.8). Operator can add sodium bicarbonate to bring water to a balanced water chemistry.
101   Improper Water Chemistry/Water Clarity
Observation: Total Alkalinity was observed at 53 ppm which is too low, the required range is 120-180 ppm. (Public Health significance) low alkalinity causes the pH to fluctuate which can lead to eye/skin irritation.
Corrective Action: Ensure that the total alkalinity is brought to a regulatory range of 80-120 ppm by adding sodium bicarbonate (soda ash).