Inspection Information:
Facility Type: | Hot Tub/Therapeutic Pool (<19 sq.m) |
Inspection type: | Follow-Up |
Inspection date: | December 16, 2009 |
Follow-up Required: | Yes |
This facility was given a high hazard rating.
More information on hazard ratings.
Chlorine (Total) Negligible |
Chlorine (Free Available) Negligible |
Chlorine (Combined) |
Bromine (Free Available) |
pH |
Total Alkalinity |
Total Hardness |
Temperature |
Clarity |
Cyanuric Acid |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
401 | Critical Inadequate concentration of disinfectant Observation: TAC & FAC was negligible. The automatic injector reservoir was empty. Corrective Action: Refill the reservoir. Done during inspection. TAC & FAC were >3.5ppm. |
402 | Critical Inadequate pH controls Observation: Before addition of chlorine, pH was 7.6. After addition it was 8.0. Corrective Action: Adjust pH to maintain = 7.8. Done PH is 7.6. |
415 | Inadequate water turnover rate Observation: Hot tub circulation pump was shut off on arrival. Corrective Action: Do not turn the circulation pump off overnight. Always leave the pump running except when backwashing or other maintenance. |
420 | Inadequate daily maintenance records Observation: The log book has not been updated since December 8, 2009. Corrective Action: Maintain records. |