Inspection Information:
Facility Type: | WS3 |
Inspection type: | Routine |
Inspection date: | May 08, 2008 |
Number of critical violations: | 0 |
Number of non-critical violations: | 3 |
Follow-up Required: | No |
This facility was given a low hazard rating.
More information on hazard ratings.
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description |
317 | Inadequate or improper construction of water works Observation: Well head cover needs to be secured- not simply sitting on top Well located at the bottom of hill of parking lot - spring melt flows past well. Corrective Action: Please slope and mound impermeable soil around the well casing to prevent melt water run off from reaching well casing. |
318 | Inadequate Microbiological Analysis data Observation: Quarterly bacteriological sampling is required Corrective Action: (no corrective action) |
320 | Other (specify below) Observation: Well information- eg well log needed (depth to water well tag, construction date) Corrective Action: (no corrective action) |