Fraser Health Authority



INSPECTION REPORT
Health Protection
229855
PREMISES NAME
Dania Home Commercial Kitchen
Tel: (604) 299-2414
Fax: (604) 299-7775
PREMISES ADDRESS
4175 Norland Ave
Burnaby, BC V5G 3S7
INSPECTION DATE
October 11, 2018
TIME SPENT
1.75 hours
OPERATOR (Person in Charge)
Penny Hill
NEXT INSPECTION DATE
4 Months
INSPECTION TYPE
Routine
ACTION TAKENFOOD SAFETY & SANITATION
ADMINISTRATIVE
Information Provided
ENFORCEMENT
Require Corrections
Comply
In Use
Food Safety Training [s. 10]
Yes
Food Safety Plan [s. 23]
Yes
Yes
Sanitation Plan [s. 24]
Yes
Yes
HAZARD RATING FOR YOUR FACILITY: Low (≤15) Total Score = 0
Critical Hazards: There are no critical hazards.
Non-Critical Hazards: Total Number: 2
209 - Food not protected from contamination [s. 12(a)]
Observation: 1) Box of rice in dry storage area was open, bag was not sealed.
2) Ready to eat desserts were stored under uncooked bacon in the walk-in cooler.
Corrective Action(s): 1) Transfer rice to pest proof/food grade container.
Corrected during inspection.
2) Store raw meat beneath ready to eat foods to prevent contamination.
Violation Score:

304 - Premises not free of pests [s. 26(a)]
Observation: 1) Mouse droppings noted on floor between wall & cooler in Nielsen/Justesen Servery
2) Cockroach (dead) noted on glueboard in fly light unit. Mgr reported cockroach issues which are being treated/addressed in the dishwashing area.
Corrective Action(s): 1) Clean up droppings & disinfect area. Continue to monitor for further activity.
2) Continue to maintain contract with Pest Control company to address cockroach issues. (Note: Treatment was provided night before).
Follow all recommendations of the Pest Control Technician
Continue to maintain a high level of sanitation
Ensure dishwashing area is thoroughly cleaned at the end of the day/night and any spills/moisture cleaned/dried.
*Caulking behind dishwashing area needs replacement.

Follow Up to "Critical" Violations Noted on Previous Inspections (if applicable): No corrections entered
Comments

-General sanitation of kitchen and servery areas was satisfactory. Some minor build-up noted along edge of floor in Mortensen & Christensen serveries. Ensure level & frequency of cleaning is increased in these areas.
-Handwashing stations in main kitchen & all serveries supplied with hot & cold running water, liquid soap & paper towel.
-Quats sanitizer solution at 200 ppm present in buckets in main kitchen & all serveries.
-Test strips present for verifying concentration staff knowledgeable about mixing/dilution procedures for sanitizer in serveries.
-Quats sanitizer from dispenser in main kitchen was 200 ppm
-Records for coolers/freezers/dishwasher temperatures present in main kitchen & serveries. Records appear to be consistently maintained. Ensure corrective action is recorded if temperature limit is not met.
-Pest Control Contract in place with Ecolab
-All kitchen/servery staff hired have Foodsafe level 1. Support Services Mgr has reviewed all certificates to ensure they are valid. Support Services Mgr has completed Foodsafe level 2 and will be completing the refresher course for Foodsafe level 1
-Staff show good hygiene; frequent handwashing, hairnets worn.

Main Kitchen
-Walk-in cooler 1 deg. C
-Walk-in freezer -12 deg. C
-True cooler (adjacent to ice machine) 3 deg. C
-Hot holding units used to transport food to serveries were >60 deg. C
-High temp. dishwasher functional. Final rinse was 77.6 deg. C
-Dry storage area organized with food stored on shelving.

Andersen Servery
-Cooler 2 deg. C
-Freezer -6 deg. C *Monitor freezer temperature. Ensure food is maintained in a frozen state. Have freezer serviced/repaired if temp does not decrease.
-High temp. dishwasher functional. Final rinse was 73.9 deg. C

Mortensen Servery
-Cooler 4 deg. C
-Freezer -15 deg. C
-Dishwasher functional & met sanitizing temp. requirement. Final rinse was 71.7 deg. C at dish surface.

Christensen Servery
-Cooler 3 deg. C
-Freezer -17 deg. C
-High temperature dishwasher functional and met sanitizing temp. required. Final rinse was 72 deg. C at dish surface.

Nielsen/Justesen Servery
-Cooler 3 deg. C
-Freezer -13 deg. C
-High temperature dishwasher functional. Final rinse was 75.7 deg. C at dish surface.

-Hot holding units (steam table) were not in use at time of inspection as it was between meals.