Fraser Health Authority



INSPECTION REPORT
Health Protection
JCHY-D32SH4
PREMISES NAME
Kohinoor Bistro and Restaurant
Tel: (604) 574-1474
Fax:
PREMISES ADDRESS
17785 56th Ave
Surrey, BC V3S 1E2
INSPECTION DATE
March 4, 2024
TIME SPENT
1 hour
OPERATOR (Person in Charge)
NEXT INSPECTION DATE
3 Months
INSPECTION TYPE
Routine
ACTION TAKENFOOD SAFETY & SANITATION
ADMINISTRATIVE
Information Provided
ENFORCEMENT
Require Corrections
Comply
In Use
Food Safety Training [s. 10]
Yes
Food Safety Plan [s. 23]
Yes
No
Sanitation Plan [s. 24]
Yes
No
HAZARD RATING FOR YOUR FACILITY: Low (≤15) Total Score = 16
Critical Hazards: Total Number: 2
205 - Cold potentially hazardous food stored/displayed above 4 °C. [s. 14(2)]
Observation (CORRECTED DURING INSPECTION): Chopped cucumber, tomatoes, and mint sauce observed to be stored out at room temperature in buffett section.
Corrective Action(s): Store aformentioned food items in cold holding units able to hold an air ambient temperature of 4C or lower.
Violation Score: 5

302 - Equipment/utensils/food contact surfaces not properly washed and sanitized [s. 17(2)]
Observation (CORRECTED DURING INSPECTION): Sanitizer spray bottles noted to be mixed with bleach and quats solution. Spray bottles not labelled.
Corrective Action(s): Prepare QUATs sanitizer spray bottles to measure at 200ppm. Label spray bottles. Do not mix multiple sanitizers.
Violation Score: 5

Non-Critical Hazards: Total Number: 2
304 - Premises not free of pests [s. 26(a)]
Observation (CORRECTED DURING INSPECTION): Rodent droppings observed underneath dry storage bins in dry storage area.
Corrective Action(s): Clean and sanitize aformentioned area to prevent rodent dropping build-up and pest harbourage.
Violation Score: 3

308 - Equipment/utensils/food contact surfaces are not in good working order [s. 16(b)]
Observation: Observed 2 chest freezer in the dry storage area to be detached. This was noted in report#258414.
Corrective Action(s): Replace or repair lid of chest freezer. Corrected by: April 1, 2024
Violation Score: 3

Follow Up to "Critical" Violations Noted on Previous Inspections (if applicable): No corrections entered
Comments

Routine Inspection conducted today.

Kitchen handwashing sinks and bar handwashing sink shared with 3-compartment sink well equipped with hot and cold running water, liquid soap, and paper towels.
2-compartment sink available. Low-temperature dishwasher measured at 100ppm chlorine final rinse. 3-compartment sink available at bar area.
Prep cooler, stand-up cooler, undercounter coolers, walk-in cooler measured at 4C or lower. Chest freezers at back of house measured at -18C. Hot-holding units for buffett measured at 60C or higher. Cold-hold unit buffett measured at 4C or lower.
Food observed to be stored at least 6 inches off the floor. Ice machine observed to be in sanitary condition. Exhaust hood vents satisfactory. Last cleaned was 3 weeks ago.

NOTE: Ensure to clean underneath shelving units in walk-in cooler, ice machine, dishwashing area to prevent food build-up. Ensure exhaust hood vents are cleaned regularly to prevent grease build-up.

Overall, facility is well organized.