Fraser Health Authority



INSPECTION REPORT
Health Protection
JVIK-BHFUAJ
PREMISES NAME
Yellowhead Trading Company
Tel: (604) 888-1223
Fax:
PREMISES ADDRESS
9044 Glover Rd
Langley, BC V1M 2R9
INSPECTION DATE
October 30, 2019
TIME SPENT
1.5 hours
OPERATOR (Person in Charge)
Robert Rogers
NEXT INSPECTION DATE
November 13, 2019
INSPECTION TYPE
Follow-Up
ACTION TAKENFOOD SAFETY & SANITATION
ADMINISTRATIVE
Information Provided
ENFORCEMENT
Require Corrections, Issue Correction Order
Comply
In Use
Food Safety Training [s. 10]
Food Safety Plan [s. 23]
Sanitation Plan [s. 24]
HAZARD RATING FOR YOUR FACILITY: Moderate (16-29) Total Score = 27
Critical Hazards: Total Number: 1
302 - Equipment/utensils/food contact surfaces not properly washed and sanitized [s. 17(2)]
Observation: Dishwasher is still not properly washing and sanitizing dishes, there is no detergent attached to the dishwasher and after the final rinse, measuring 0-10ppm Cl
Corrective Action(s): Service or replace the dishwasher to ensure the following:
- An appropriate detergent is connected to the dishwasher and it is being drawn into the unit
- Consistent residual sanitizer concentration of 50ppm Cl. To be verified with test strips

In the interim, operator will be testing every load with test strips to verify 50ppm Cl until it has been repaired or replaced. This is to be completed by November 13th or enforcement action will follow as per Correction Order.
Violation Score: 15

Non-Critical Hazards: Total Number: 2
306 - Food premises not maintained in a sanitary condition [s. 17(1)]
Observation: Ensure all surfaces are smooth, easily cleanable and impermeable - observed bare wood in several areas
Cleaning has improved, however still requires work in the following areas:
Corrective Action(s): - Back prep area - including, shelves, walls, floor
- Inside prep cooler
- Seal all bare wood
- Storage rack
Violation Score: 3

308 - Equipment/utensils/food contact surfaces are not in good working order [s. 16(b)]
Observation: Dishwasher has not been appropriately serviced and is testing at 0 - 10 ppm Cl
Corrective Action(s): Service or replace dishwasher
- Ensuer dishwasher has an appropriate detergent and tests at 50ppm Cl after final rinse cycle as per Correction Order.

To be corrected by November 13, 2019
Violation Score: 9

Follow Up to "Critical" Violations Noted on Previous Inspections (if applicable): No corrections entered
Comments

Prep cooler has been repaired and is now maintaining less than 4C - thank you
Cleaning has improved, however some work is still required - see 306
Observed one sanitizer spray bottle at 100ppm Cl - provide additional spray bottles for front area as well. Fantastik is to be stored in chemical storage area when not in use for non-food contact surface
All items hot held > 60C at time of inspection
Lighting has improved in back area, thank you.