Fraser Health Authority



INSPECTION REPORT
Health Protection
BCUD-AYCQ67
PREMISES NAME
Aqua Blue Water & Filtration
Tel: (604) 597-2074
Fax:
PREMISES ADDRESS
13387 72nd ave
Surrey, BC V3W 2N5
INSPECTION DATE
May 1, 2018
TIME SPENT
0.75 hours
OPERATOR (Person in Charge)
Jeff Naylor
NEXT INSPECTION DATE
May 08, 2018
INSPECTION TYPE
Routine
ACTION TAKENFOOD SAFETY & SANITATION
ADMINISTRATIVE
Information Provided
ENFORCEMENT
Require Corrections
Comply
In Use
Food Safety Training [s. 10]
Food Safety Plan [s. 23]
Sanitation Plan [s. 24]
HAZARD RATING FOR YOUR FACILITY: Low (≤15) Total Score = 8
Critical Hazards: Total Number: 1
401 - Adequate handwashing stations not available for employees [s. 21(4)]
Observation: Cold water turned off at hand washing station. Hot water is too hot to reasonably wash hands for 20-30 seconds
Corrective Action(s): Turn on the cold water so people (staff) can wash their hands properly, and without scalding.
Violation Score: 5

Non-Critical Hazards: Total Number: 1
209 - Food not protected from contamination [s. 12(a)]
Observation: Bottles are getting washed/ rinsed/ sanitized using a "sterilizer" powder chemical at an unknown concentration.
Your newly added (without health approval) machine has an adequate wash temperature of 135-140F but not sanitize temperature.
Corrective Action(s): A safety plan is to be submitted to your EHO for approval. Once verified adequate by your EHO, your staff must be well versed in how to handle the "sterilizer" chemical that is on site.
Violation Score: 3

Follow Up to "Critical" Violations Noted on Previous Inspections (if applicable): No corrections entered
Comments

Note: a follow up inspection will occur in 1 week. The above Safety Plan is required prior to my reinspection
On this Safety Plan you must include:
- what your chemical is
- how to use the chemical to sanitize your bottles
- at what concentration will you use the chemical, and how will you check it?
- what is the tank volume of your new bottle washer (this is needed to understand how much sanitizer to add)

Water source is potable City water. Extra filtration provided.