Fraser Health Authority



INSPECTION REPORT
Health Protection
ZDER-ACGUYY
PREMISES NAME
The Mulberry Retirement Residence - Food Service
Tel: (604) 526-2248
Fax: (604) 526-2278
PREMISES ADDRESS
7230 Acorn Ave
Burnaby, BC V5E 4N9
INSPECTION DATE
August 3, 2016
TIME SPENT
1 hour
OPERATOR (Person in Charge)
Earl Bergen
NEXT INSPECTION DATE
6 Months
INSPECTION TYPE
Routine
ACTION TAKENFOOD SAFETY & SANITATION
ADMINISTRATIVE
Information Provided
ENFORCEMENT
Require Corrections
Comply
In Use
Food Safety Training [s. 10]
Yes
Food Safety Plan [s. 23]
Yes
Yes
Sanitation Plan [s. 24]
Yes
Yes
HAZARD RATING FOR YOUR FACILITY: Low (≤15) Total Score = 3
Critical Hazards: There are no critical hazards.
Non-Critical Hazards: Total Number: 1
308 - Equipment/utensils/food contact surfaces are not in good working order [s. 16(b)]
Observation: Dish pit handsink noted at 51 C. Scolding hands during handwashing. Liquid soap and paper towel provided.
Corrective Action(s): Ensure water temperature is under 49 C (ideally 38 C) to allow for proper handwashing. Sink has premix valve that runs too hot during the slow periods of operation and cooler while the dishwasher is operating. Adjust temperature to handsink or change handsink with adjustable taps/temperature knobs.
Violation Score: 3

Follow Up to "Critical" Violations Noted on Previous Inspections (if applicable): No corrections entered
Comments

1.Walk in cooler: 2 C / Freezer: -18 C
2. Prep coolers: 4 C / cooler drawers: 3 C
3. Coffee cooler: 3 C
4. Hot holding baths: 72 -80 C (soup)

-High temp dishwasher noted 72.8 C at the plate
-Sanitizer bottles are labelled and noted at 200 ppm QUATs in kitchen
-Sanitizer dispenser source noted: 200 ppm QUATS
-All hand sinks fully supplied with hot & cold water, liquid soap and paper towel

-All food appears to be covered, stored off the ground and organized.
-No signs of pest activity noted - pest control provided by Orkin
-Ice machine maintained in sanitary condition
-General sanitation appears satisfactory

*Ceiling fan cover loose - hanging from 2 secure lines instead of the 4. Cover is swinging and requires additional securement. Operator has called it in for servicing