209 - Food not protected from contamination [s. 12(a)]
Observation: 1. Opened bag of dry ingredient stored on floor in Cake Side Mixing Room.
2. Cooling Cakes stored beside garbage bin and warewashing sinks. Cakes were then brought through the cake processing room where cleaning and sanitizing was actively taking place. Spray from hoses could potentially contaminate cakes as well as water from floor can splash onto cakes as they were brought through the processing room to access the tempering room.
Corrective Action(s): 1. Store all food products at least 6" (15 cm) off the ground to protect from contamination.
- Review procedures with staff. Do not store any food directly on the ground.
2. Organize timing between procedures. Ensure that cakes are protected from contamination at ALL times. It may be necessary to cover cake carts as they get pulled through the cake processing room if the room is undergoing cleaning and sanitizing procedures. Review procedures accordingly.
[Correction Date: August 14, 2017]
Violation Score: 9
308 - Equipment/utensils/food contact surfaces are not in good working order [s. 16(b)]
Observation: 1. Tape used to tape side panel of Tonelli Mixer.
2. High Temperature Sanitizing Pan Washer is not operating properly. Unit is not heating up.
Corrective Action(s): 1. Remove tape. Repair/ address side panel issue. [Correction Date: August 14, 2017]
- Surfaces of food equipment must be smooth, non-absorbent, and easily cleanable. Pieces of tape may also potentially contaminate food.
2. Repair and/ or adjust High Temperature Sanitizing Pan Washer. Minimum Wash and Final Rinse Temperatures must be achieved as per unit data plate.
[Correction Date: August 14, 2017]
Violation Score: 15
311 - Premises not maintained as per approved plans [s. 6(1)(b)]
Observation: - Flooring in several processing areas has worn off/ peeled away or is pitting.
- Cracks noted in Bake Side Walk-In Cooler floor.
Corrective Action(s): - Repair/ seal affected flooring.
- Fill/ seal floor cracks.
[Correction Date: October 31, 2017]
*Floor surfaces must be smooth, non-absorbent, and easily cleanable.
Violation Score: 3
|