A routine inspection of the temporary Deli Dept. was conducted, the following observations were made:
- Temporary premises built as per approved plans. Temp. deli situated where the Seafood Dept. was (premises temporarily has no Seafood Dept.).
- Coolers were 1C; thermometers present; and temperatures recorded daily.
- Unable to test hot holding cases as not turned on.
- Quats sanitizer was 200-400ppm.
- Hand sink stocked with liquid soap, paper towels, and running hot and cold water.
- 3-comp. sink installed for warewashing.
- Raw proteins (whole chickens) stored separately from RTEs foods in the small walk-in-cooler in the temp. Deli section.
- Ventilation for the ovens to be installed soon. Do not operate the ovens until the exhaust system has been installed to remove odor, heat, and grease laden vapors.
- Surfaces are smooth, sealed, cleanable, light colored, durable, and impervious to water.
- FoodSafe certified staff present.
- Existing "warehouse" walk-in-cooler for the Deli Dept. still in use.
- Permit to operate the temporary Deli area granted. |