306 - Food premises not maintained in a sanitary condition [s. 17(1)]
Observation: Debris/ buildup noted on the door (interior) of the ABI dish machine.
Corrective Action(s): Wash and sanitize the ABI dish machine and have that included in the Sanitation Schedule to ensure that it gets cleaned as required.
Date to be corrected by: Today
Violation Score: 3
308 - Equipment/utensils/food contact surfaces are not in good working order [s. 16(b)]
Observation: 1. ABI dish machine: High temperature dish machine was able to reach 74.1C at the plate level during the rinse cycle, however at the rinse temperature gauge, the highest temperature it was able to attain during the rinse cycle was 75.0C (must show 82.0C) at the rinse temperature gauge).
2. Ruby/ Emerald dish machine: Non-functioning during the inspection. As per Manager and staff, the dish machine was running properly and showed 180F at the rinse temperature gauge during the rinse cycle. However, during the inspection, the machine would only run the wash cycle and after a long time will not get to the rinse cycle.
Corrective Action(s): 1. Fix the rinse temperature gauge to allow staff to be able to determine that the high temperature dish machine is functioning properly, that it is able to sanitize all dishware properly during the rinse cycle. Alternatively, the facility has a water-proof thermometer with a max. and min. function (during the inspection, reviewed how to use this thermometer with the Director). Use this water-proof thermometer instead to check that the dish machine is able to reach at least 160F or 71C at the plate level during the rinse cycle. If the rinse temperature gauge is malfunctioning, then the staff will not be able to determine if the dishmachine is effective at removing all harmful bacteria off the dishwares.
2. Director of Dietary Services placed a "Do Not Use" signage on the malfunctioning dish machine and has communicated to staff to use the one that is working in the upstairs servery until they can properly assess if they can get the machine to sanitize at the proper temperature with the water-proof thermometer or have the unit serviced before they can resume using the machine.
Date to be corrected by: January 13, 2023
Violation Score: 3
|