Fraser Health Authority



INSPECTION REPORT
Health Protection
KKIM-C42TU6
PREMISES NAME
A&W #0173 (Lougheed Mall)
Tel:
Fax:
PREMISES ADDRESS
CRU909 - 9855 Austin Rd
Burnaby, BC V3J 1N4
INSPECTION DATE
June 16, 2021
TIME SPENT
1.25 hours
OPERATOR (Person in Charge)
Adieba Mirbaz
NEXT INSPECTION DATE
6 Months
INSPECTION TYPE
Routine
ACTION TAKENFOOD SAFETY & SANITATION
ADMINISTRATIVE
Information Provided
ENFORCEMENT
Require Corrections
Comply
In Use
Food Safety Training [s. 10]
Yes
Food Safety Plan [s. 23]
Yes
Yes
Sanitation Plan [s. 24]
Yes
No
HAZARD RATING FOR YOUR FACILITY: Low (≤15) Total Score = 5
Critical Hazards: Total Number: 1
302 - Equipment/utensils/food contact surfaces not properly washed and sanitized [s. 17(2)]
Observation (CORRECTED DURING INSPECTION): 3rd sink in 3 compartment sink is filled up with washed equipment & utensils without any sanitizer. Asked employee how warewashing is done and it was stated that equipment/utensils are rinsed with water after being soaked in the detergent solution. Sanitizing step is absent.
Corrective Action(s): All equipment was removed in the 3rd sink and it was filled up with 200ppm QUAT sanitizer at the time of inspection. Ensure to immerse every equipment/utensils in 200ppm QUAT solution after rinsing. Immerse for minimum of 1 minute and let air dry.
Violation Score: 5

Non-Critical Hazards: There are no non-critical hazards.
Follow Up to "Critical" Violations Noted on Previous Inspections (if applicable): No corrections entered
Comments

All handsinks fully equipped.
All cooling units at 4C or below.
All freezer units range from -10C to -18C.
All hot holding units at 60C or above.
Condiments at room temperature being time monitored; discarded every 4 hours.
QUAT sanitizer solution in buckets measured at 200ppm with test strips.
Vent grills in sanitary condition.
General sanitation is good.

COVID protocols:
- employees have masks worn.
- plexiglass barrier installed at the front counter.
- OXIVIR disinfectant available for disinfecting non-food contact surfaces.

* Ensure to air-dry washed equipment on drying rack, not in the sink. Reorganize the equipment shelves to allow more space for drying.