INSPECTION REPORT
Health Protection
JELR-CZU2RV
PREMISES NAME
The Zen
Tel: (604) 649-0000
Fax:
PREMISES ADDRESS
222 - 1077 56th St
Delta, BC V4L 2A2
INSPECTION DATE
January 25, 2024
TIME SPENT
0.75 hours
OPERATOR (Person in Charge)
NEXT INSPECTION DATE
6 Months
INSPECTION TYPE
Follow-Up
ACTION TAKENPSE SERVICE TYPES
ADMINISTRATIVE
ENFORCEMENT
Require Corrections
Nail Services, Esthetics, Other
    Non-registered Massage
HAZARD RATING FOR YOUR FACILITY: Moderate (16-29) Total Score = 24
Critical Hazards: Total Number: 1
211 - Semi critical items not adequately cleaned and disinfected
Observation (CORRECTED DURING INSPECTION): Metal foot file must be fully immersed in high level disinfectant.
Corrective Action(s): Fully immerse metal foot file and make sure that the disinfectant is changed regularly as per label (and is not cloudy). Follow directions for safe and proper use of this chemical. Keep track of date when disinfectant is changed.
Violation Score: 15

Non-Critical Hazards: Total Number: 1
221 - Employee lacks adequate personal hygiene and/or hand washing practices
Observation (CORRECTED DURING INSPECTION): Alternate sink is used for hand washing. Hand sink in room is dry and has not been recently used.
Corrective Action(s): Use sink in nail and esthetics room for hand washing and clean up. Use warm water, liquid soap, and single use hand drying towels.
Violation Score: 9

Follow Up to "Critical" Violations Noted on Previous Inspections (if applicable)
Code 317 noted on Routine inspection # JELR-CL6UJT of Nov-14-2022
Biomedical waste and/or sharps not disposed of in an adequate manner
Observation: Lancets for pimples and pedicure blades for callus removal are to be disposed of into a sharps container (none available).
Correction: Operator will be providing a sharps container prior to next use of needles or blades and to provide email confirmation to EHO.
Comments

Follow up inspection:
***Hand washing sink - use the sink in the treatment room to hand wash before client and to clean implements after each client.
- Provide hand soap for use with warm water for proper hand washing (hand sanitizer is not as effective with water).
- Sharps container provided. Use this to dispose of pedicure blades. Blade handle is disinfected with high level disinfectant.
- Metal foot file - ensure it is fully immersed in high level disinfectant as previously discussed.
- Do not use implements that cannot be properly disinfected (cuticle implement with red plastic handle).
- Your high level disinfectant is cloudy and must be changed frequently (every 14 days or less). Follow directions on label.
- Wide absorbent file and regular absorbent nail file - on tray - discard these if they have been used or send home with client. These items are "single use only" and cannot be properly cleaned and disinfected.
- New brochures do not advertise ear candling (service not permitted).
Inspection carried out with operator and information provided to operator.