Inspection Information:
Facility Type: | Restaurant |
Inspection type: | Follow-Up |
Inspection date: | January 22, 2014 |
Number of critical violations: | 1 |
Number of non-critical violations: | 0 |
Follow-up Required: | Yes |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
507 | Critical Equipment, utensils and food surfaces are washed and sanitized (Sec 17(2)) Observation: The bar glass washer has not yet been repaired. No detectable sanitizer observed in the rinse cycle this time. Uncorrected critical violation. Corrective Action: Please get the bar glasswasher serviced by a qualified technician so that it provides 12.5 ppm iodine in the rinse cycle. In the meantime, serve drinks in disposable cups. |
Comments:
Spoke with the bar manager on the phone and advised her to switch to disposable cups until glass washer is repaired.
A follow up inspection required.