Inspection Information:
Facility Type: | Restaurant |
Inspection type: | Routine |
Inspection date: | March 24, 2014 |
Number of critical violations: | 0 |
Number of non-critical violations: | 5 |
Follow-up Required: | No |
Violations:
A summary of the violations found during the inspection are listed below.
Code | Description / Observation / Corrective Action |
116 | Improper Construction / Maintenance of Establishment Observation: The rubber seal on the slider door of the front display case is brittle and damaged, allowing cold air to escape despite the door being closed. Corrective Action: Replace the rubber seal. |
503 | Equipment/utensils/food contact surfaces are in good working order (Sec 16(b)) Observation: Freezer #9 was not working at time of inspection. All food items already removed. Corrective Action: Operator indicated a replacement freezer will be purchased. Until the new freezer is installed, ensure dry foods are not stored directly under the condensate drip tray on the back of the broken freezer. This was discussed during last year's inspection also. |
504 | Equipment/utensils/food contact surfaces are operated in a safe/sanitary manner (Sec 16(c)) Observation: Spoons for frothing hot drinks were being stored in an insert of tepid water. Corrective Action: All equipment used for making drinks must be stored in a manner that is protected from contamination. This can include any of the following methods: stored in sanitizing solution (100ppm chlorine), stored in a functioning dipper well (not currently available on site), or stored dry and washed frequently in the high temperature dishwasher. |
504 | Equipment/utensils/food contact surfaces are operated in a safe/sanitary manner (Sec 16(c)) Observation: Wiping cloth used for steamer wand is not stored in a sanitary manner in between uses. Corrective Action: Store the wiping cloth in a sanitizing solution of 100ppm chlorine. |
505 | Food premises maintained in a sanitary condition (Sec 17(1)) Observation: Some areas of the kitchen could benefit from a thorough cleaning where cobwebs, dust and debris accumulation was noted. Corrective Action: Thoroughly clean the following areas: behind the metal rack at the back corner of the kitchen (by the 2 compartment sink), under and behind the small black bar fridge at the front counter, floors in the proofer, under and behind the dishwasher and sink (where chemicals are stored). Also reorganize chemicals so nothing is stored directly on the floor. |
506 | Equipment/utensils are maintained in a sanitary condition (Sec 17(1a)) Observation: There is no evidence of recent servicing/cleaning of the commercial ventilation system. Corrective Action: Have this system serviced/cleaned by a professional. |
Comments:
A routine inspection was conducted, the following items were in compliance with the Food Premises Regulation:
- Hand washing stations are equipped with liquid soap and paper towel.
- Dishwasher final rinse cycle measured 75.5C at the plate with water-proof thermometer.
- All refrigeration equipment measured 4C or less.
- Hot holding soup measured >60C.
- Thermometers noted in all coolers and freezers.
- Daily temperature log is up to date.
- Foodsafe trained staff on site at time of inspection.
A number of structural upgrades were discussed and agreed upon during the last inspection (April 2, 2013). None of these items have been completed and remain outstanding:
- All lights require shatterproof covers.
- Dishwashing area redesign (installation of 2 compartment sink with spray wand, increase shelving space for chemical storage, reposition dishwasher under counter, create space for receiving dirty dishes (discontinue using counter across from sandwich station).
- Pest proof the back screen door.
- Install a designated hand sink in the back kitchen for bakers.
A time line for completion of these items will be discussed at our follow-up inspection in 2 weeks (April 7, 2014).