Routine inspection conducted
There is the main upstairs kitchen, the bar area, and the downstairs prep kitchen (which is mostly for cold food/salad prep, but has several freezers and a walk in cooler).
Main kitchen:
Handsinks equipped with liquid soap, paper towels, hot/cold running water
Walk in cooler at 3.0 deg C
With exception of above mentioned cooler drawer, all other coolers at 4 Deg C or less
All freezers at -18 deg C or less
Thermometers present in coolers and freezers
Quat spray sanitizer at 200 ppm QUATS
Bleach rag bucket at 100 ppm chlorine residual
High temperature dishwasher achieved 73.6 deg C on rinse cycle at dish level (minimum 71 deg C required)
Downstairs kitchen:
Walk in cooler was being defrosted and not in use at time of inspection. No foods were stored inside.
Walk in freezers and upright freezers at -18 deg C or less
3 compartment sink available on site for vegetable washing, but dishes are brought upstairs for washing/sanitizing
Hot/cold running water, liquid soap, paper towels available at handsink
Quat spray sanitizer available at 200 ppm Quats
General sanitation in downstairs kitchen is excellent
Temperature logs maintained
Bar area:
Iodine glass washer at 12.5 ppm iodine on rinse cycle
Beverage walk in cooler at 3.2 deg C
Handsink in bar area is stocked with liquid soap and paper towels
|