302 - Equipment/utensils/food contact surfaces not properly washed and sanitized [s. 17(2)]
Observation (CORRECTED DURING INSPECTION): Commercial dishwasher does not have a final sanitizing rinse. Water temperature only 60C as shown on the final rinse water gauge (gauge near hot water booster). Thermometer inside of machine reached 65C (which is the temperature shown on the bottom, wash water gauge). When the hot water booster was adjusted, there was a water leak from the booster (top of dishwasher).
Corrective Action(s): Immediately use single use (disposable) utensils and containers for customer food. All pots, cutting boards, bowls, and other utensils are to be washed with detergent and water, rinsed, and then sanitized in a chlorine solutions of 100-200ppm for 2 hours. Air dry.
Violation Score: 25
401 - Adequate handwashing stations not available for employees [s. 21(4)]
Observation (CORRECTED DURING INSPECTION): Liquid soap in an easy to use pump dispenser is not available at the kitchen hand sink.
Corrective Action(s): Provided during inspection (bottle from women's washroom). All hand washing sinks, including washroom hand sinks, are to have easy to use liquid soap and paper towels to make it easier for food handlers to wash hands.
Violation Score:
|